DSpace Repository

Seismic response of base-isolated liquid storage tanks

Show simple item record

dc.contributor.author SHRIMALI, MK en_US
dc.contributor.author JANGID, RS en_US
dc.date.accessioned 2011-08-29T02:19:30Z en_US
dc.date.accessioned 2011-12-26T12:58:20Z en_US
dc.date.accessioned 2011-12-27T05:48:02Z
dc.date.available 2011-08-29T02:19:30Z en_US
dc.date.available 2011-12-26T12:58:20Z en_US
dc.date.available 2011-12-27T05:48:02Z
dc.date.issued 2003 en_US
dc.identifier.citation JOURNAL OF VIBRATION AND CONTROL, 9(10), 1201-1218 en_US
dc.identifier.issn 1077-5463 en_US
dc.identifier.uri http://dx.doi.org/10.1177/107754603030612 en_US
dc.identifier.uri http://dspace.library.iitb.ac.in/xmlui/handle/10054/11920 en_US
dc.identifier.uri http://hdl.handle.net/10054/11920
dc.description.abstract We investigate the seismic response of liquid storage tanks isolated by lead-rubber bearings. The force-deformation behavior of the bearings is considered as bi-linear modeled by the Wen equation. The continuous liquid mass of the tank is modeled as a sloshing mass, impulsive mass and rigid mass. The corresponding stiffness associated with these masses has been worked out depending upon the properties of the tank wall and liquid mass. The governing equations of motion of the three-degrees-of-freedom model of the isolated liquid storage tank are derived. Since the force-deformation behavior of the bearings is non-linear, as a result, the seismic response is obtained using the Newmark step-by-step method under several recorded earthquake ground motions. The responses of two types of tanks, namely slender and broad, are compared with the corresponding response without an isolation system in order to investigate the effectiveness of the isolation system. A parametric study is also carried out to study the effects of important system parameters on the effectiveness of seismic isolation for liquid storage tanks. The various important parameters considered are the aspect ratio of the tank, period, damping and the yield strength of the isolation system. It has been observed that the seismic isolation of the tanks is quite effective and the response of isolated liquid storage tanks is significantly influenced by the above system parameters. There is an optimum value of isolation damping for which the base shear in the tank attains the minimum value. Therefore, increasing the bearing damping beyond a certain value decreases the bearing and sloshing displacements but it increases the base shear. en_US
dc.language.iso en en_US
dc.publisher SAGE PUBLICATIONS LTD en_US
dc.subject Performance en_US
dc.subject Earthquake en_US
dc.subject Vibration en_US
dc.subject Design en_US
dc.subject.other Lead-Rubber Bearing en_US
dc.subject.other Liquid Storage Tank en_US
dc.subject.other Earthquake en_US
dc.subject.other Base Isolation en_US
dc.subject.other Seismic Response en_US
dc.subject.other Aspect Ratio en_US
dc.subject.other System Parameters en_US
dc.title Seismic response of base-isolated liquid storage tanks en_US
dc.type Article en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account