Heat transfer characteristics of water flowing through micro-tube heat exchanger with variable fluid properties

Show simple item record

dc.contributor.author KUMAR, R
dc.contributor.author MAHULIKAR, SP
dc.date.accessioned 2021-03-19T16:52:05Z
dc.date.available 2021-03-19T16:52:05Z
dc.date.issued 2020
dc.identifier.citation JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY 140(4)1919-1934 en_US
dc.identifier.issn 1388-6150
dc.identifier.issn 1588-2926
dc.identifier.uri https://doi.org/10.1007/s10973-019-08937-8
dc.identifier.uri http://localhost:8080/xmlui/handle/100/32325
dc.description.abstract The heat transfer characteristics of laminar single-phase forced convective water flow through a micro-tube heat exchanger are numerically investigated in this paper. Two-dimensional simulations are performed to find the effects of variable fluid properties on heat transfer for hydrodynamically and thermally developed flow. The effects of variable fluid properties on convective heat transfer coefficient (h) and Nusselt number (Nu) are significant for micro-convective flow. It is noted that the variation in temperature-dependent thermal conductivity [k(T)] greatly enhances the h as compared to the variation in temperature-dependent viscosity [mu(T)], although water viscosity-temperature sensitivity (S mu T) is greater than that of thermal conductivity-temperature sensitivity (SkT). The effects of variation in wall heat flux (q '' w) and inlet temperature on heat transfer are investigated for variable fluid properties. It is noted that the Nu declines with an augment in q '' w for temperature-dependent density variation [.(T)]. The Nu increases with an increase in q '' w for mu(T) and k(T) variations. The results show that the Nu decreases with an increase in inlet temperature for variable fluid properties. The undevelopment and redevelopment of the flow are observed due to mu(T) variation. Additionally, the effects of wall heat flux, inlet temperature and inlet velocity on the variation of Nu/Pr1/3 with Re are examined for mu(T) variation. en_US
dc.language.iso English en_US
dc.publisher SPRINGER en_US
dc.subject MICRO-CHANNEL en_US
dc.subject FULLY DEVELOPED FLOW en_US
dc.subject HEAT TRANSFER en_US
dc.subject VARIABLE FLUID PROPERTIES en_US
dc.subject FLOW UNDEVELOPMENT en_US
dc.subject TEMPERATURE-DEPENDENT VISCOSITY en_US
dc.subject LAMINAR FORCED-CONVECTION en_US
dc.subject PRESSURE-DROP en_US
dc.subject SILICON MICROCHANNELS en_US
dc.subject VISCOUS DISSIPATION en_US
dc.subject THERMAL DEVELOPMENT en_US
dc.subject CIRCULAR TUBE en_US
dc.subject FRICTION en_US
dc.subject PERFORMANCE en_US
dc.subject MOMENTUM en_US
dc.title Heat transfer characteristics of water flowing through micro-tube heat exchanger with variable fluid properties en_US
dc.type Article en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account