DSpace Repository

Evaluation of dynamic sky-type using novel angular sky luminance measurement system

Show simple item record

dc.contributor.author MASKARENJ, M
dc.contributor.author CHAWLA, G
dc.contributor.author BANERJEE, R
dc.contributor.author GHOSH, PC
dc.date.accessioned 2018-12-03T07:24:43Z
dc.date.available 2018-12-03T07:24:43Z
dc.date.issued 2018
dc.identifier.citation BUILDING AND ENVIRONMENT,146()152-165 en_US
dc.identifier.issn 0360-1323;1873-684X
dc.identifier.uri http://dx.doi.org/10.1002/2014GL060099
dc.identifier.uri http://dspace.library.iitb.ac.in/xmlui/handle/100/22770
dc.description.abstract Standard sky-types of the established Commission International de l'Eclairage (CIE) sky-models are employed for generating sky-luminance distribution datasets in most building daylight simulation packages, which are used for predicting indoor illuminance distribution. However, sky-type can vary on diurnal and seasonal basis; and there is a need for identifying closest sky-type at different time-points for better indoor illuminance predictions. This paper aims at recommending closest sky-model for measured angular sky-luminance distribution sets through comparison with established CIE standard skies. A novel design of sky-luminance measurement device using calibrated Light Dependent Resistors is proposed to measure incident illuminance from 265 discrete sky positions every 5 min. Statistical analysis is performed on 143,100 distinct data-points corresponding to 540 representative datasets measured across 5-month period at Mumbai, and the closest CIE sky-type for various hours is recommended based on frequency of occurrence. A range of 9 sky-types of the CIE sky-model was determined as closest model sky-set, with sky-types 2, 4, 5, 6, 7, 8, 10, 11 and 13 assessed as closest sky-type for different time-points across the measured datasets. CIE sky-type 8 is identified dominating over 50% of measured datasets - 51.6% in November, 53.6% in January, 52.6% in March and 71.5% in April. Measured sky distribution is observed to generally follow trend of overcast to intermediate to clear sky-types in morning hours, and opposite in evening hours. This approach of recommending closest sky-type as simulation input as against using generic sky-types can enhance the accuracy of building indoor daylight predictions. en_US
dc.language.iso English en_US
dc.publisher PERGAMON-ELSEVIER SCIENCE LTD en_US
dc.subject Building daylight modelling en_US
dc.subject CIE sky model en_US
dc.subject Angular sky luminance distribution en_US
dc.subject Temporal sky-type recommendation en_US
dc.subject Indoor daylight prediction en_US
dc.subject Sky scanner en_US
dc.subject DAYLIGHT FACTORS en_US
dc.subject HONG-KONG en_US
dc.subject ENERGY en_US
dc.subject DESIGN en_US
dc.subject BUILDINGS en_US
dc.subject PERFORMANCE en_US
dc.subject ILLUMINANCE en_US
dc.subject SIMULATION en_US
dc.subject MODEL en_US
dc.title Evaluation of dynamic sky-type using novel angular sky luminance measurement system en_US
dc.type Article en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account