DSpace Repository

Estimation of the Park-Ang damage index for planar multi-storey frames using equivalent single-degree systems

Show simple item record

dc.contributor.author GHOSH, S en_US
dc.contributor.author DATTA, D en_US
dc.contributor.author KATAKDHOND, AA en_US
dc.date.accessioned 2012-06-26T06:41:53Z
dc.date.available 2012-06-26T06:41:53Z
dc.date.issued 2011 en_US
dc.identifier.citation ENGINEERING STRUCTURES,33(9)2509-2524 en_US
dc.identifier.issn 0141-0296 en_US
dc.identifier.uri http://dx.doi.org/10.1016/j.engstruct.2011.04.023 en_US
dc.identifier.uri http://dspace.library.iitb.ac.in/jspui/handle/100/14064
dc.description.abstract A detailed characterization of potential structural damage is essential to performance-based seismic design. The Park-Ang damage index is selected in this work as the seismic damage measure, since it is one of the most realistic measures of structural damage. Response spectra constitute the most common tool used for characterizing the seismic hazard at a site, and these spectra represent the demand on single-degree oscillators. To use these spectra for estimating the Park-Ang damage index demand on an MDOF system, three equivalent single-degree system-based approximate schemes are proposed. These schemes are tested on three moment resisting frames under several ground motion scenarios. The effectiveness of an equivalent system scheme is measured by comparing with the estimates from a nonlinear response-history analysis of the MDOF model. These schemes are tested for both global and storey-level damage indices. Variation of the non-dimensional parameter beta is also considered in these case studies. Overall, all the three schemes are found to be effective with varying degrees of accuracy. The proposed methods are recommended for damage-based seismic design and performance evaluation of structures because these schemes can use response spectra for demand estimation and reduce computation cost. (C) 2011 Elsevier Ltd. All rights reserved. en_US
dc.language.iso English en_US
dc.publisher ELSEVIER SCI LTD en_US
dc.subject Modal Pushover Analysis en_US
dc.subject Hysteretic Energy Demand en_US
dc.subject Reinforced-Concrete en_US
dc.subject Seismic Damage en_US
dc.subject R/C Frames en_US
dc.subject Design en_US
dc.subject Buildings en_US
dc.subject Model en_US
dc.subject State en_US
dc.subject.other Park-Ang Damage Index en_US
dc.subject.other Equivalent Systems en_US
dc.subject.other Modal Pushover Analysis en_US
dc.subject.other Performance-Based Evaluation en_US
dc.subject.other Performance-Based Design en_US
dc.title Estimation of the Park-Ang damage index for planar multi-storey frames using equivalent single-degree systems en_US
dc.type Article en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account